Improve animal welfare, production, and profitability in pig complexes with the patented Infraconic. This radiant heat pig brooder leads the industry in heat efficiency, range of heat outputs, flexible installation and proven reliability.

L.B. White designed the Infraconic to save money on energy costs – up to 40% fuel cost savings depending on the facility condition and existing pig heating system.

The Infraconic provides a more consistent heat pattern than other brooders for pig production. As a result, pigs remain warm so they eat more and grow at a faster rate. Pork producers around the world rely on the L.B. White radiant heat brooder for farrowing, nursery and wean to finish phases of pig production.

Infraconic brooder heaters in a swine building.

Key Features of L.B. White Infraconic Brooder Heaters

  • Wide range of models from 2,800 to 17,100 Btu/h
  • Zone or individual control
  • Manual or spark ignition
  • Fully assembled and ready to install
  • 100% Test fired
  • Components highly resistant to corrosion

Key Benefits of L.B. White Pig Brooders

  • Lasts longer than competitors' brooders
  • Easy to light and maintain continuous operation
  • Burns clean across the entire operating range
  • Heats more efficiently and provides better pig coverage than other brooders

Infraconic radiant heat brooders integrate with environment control systems, including:

  • AP Systems (Automated Production Systems)®
  • Big Dutchman - Viper®
  • Dicam®
  • Fancom®
  • Hotraco®
  • Maximus
  • Rotem®
  • Val-Co®
  • and more

Pig Brooder Installation

View this brooder heater installation diagram or download the owner's manual to see complete installation instructions for your Infaconic brooder heater.

infraconic Brooders in a swine building.

Determine Size and Quantity of Brooder Heaters for Ventilated Pig Production Buildings

Call our technical experts to help you select the correct size and quantity of L.B. White radiant heat brooders for your swine enterprise. For Technical Support, call 1-800-345-7200 or 608-783-5691.

Specifications of Infraconic Pig Brooder Heaters

  I-3
Pig
Brooder
I-5
Pig
Brooder
I-17
Pig
Brooder

Btu/h Rating
(maximum input)

2,800

5,200 17,100
Ignition Types Manual Manual

Manual /
Spark

Electrical Supply
(Voltz/Hz/Phase)

n/a n/a 120/60/1 (Spark)
Fuel Types

LP
Natural Gas

LP
LP
Natural Gas

Fuel
Consumption

per Hour

LP
.13 lbs./hr

NG
2.8 CFH

LP
.24 lbs./hr

NG
5.2 CFH

LP
.80 lbs./hr

NG
17.1 CFH

Pig Coverage
per Heater
30 Pigs

Manual (170 Pigs)
Spark (125 Pigs)

Installation
(brooder to floor)

24” above
piglet creep zone

3-4 feet above
pig zone floor

4-5 feet above
pig zone floor


Zone Controls for Pig Brooder Heaters

Standard Zone Panel - Brooder Controls

Ignition Type

Part #

Description

Manual Ignition Brooders

09688-D

Control: standard
Brooder Capacity: 14 (LP), 8 (NG)
Electrical Requirement: 120V/60Hz/1

Manual Ignition Brooders

09856-D

Control: standard
Brooder Capacity: 40 (LP or NG)
Electrical Requirement: 120V/60Hz/1

Manual Ignition Brooders

09959

Control: house control - on/off

Brooder Capacity: 40 (LP or NG)

Electrical Requirement: 120V/60Hz/1

Includes: sensor bracket

Manual Ignition Brooders

22553

Control: house control - dual stage

Brooder Capacity: 40 (LP or NG)

Electrical Requirement: 120V/60Hz/1

Includes: sensor bracket

Auto Modulating Zone Panel - Brooder Controls

Ignition Type

Part #

Description

Manual Ignition Brooders

28543

Control: house control
Brooder Capacity: 24 (LP or NG)
Electrical Requirement: 24 VDC Power Supply and a 0-10 VDC control signal from the house control
Includes: sensor bracket

Manual Ignition Brooders

28564

Control: SmartBox control
Brooder Capacity: 24 (LP or NG)
Electrical Requirement: 24 VDC Power Supply and pwm control signal
Includes: sensor bracket

Manual Ignition Brooders

29537

Control: house control
Brooder Capacity: 40 (LP or NG)
Electrical Requirement: 24 VDC Power Supply and a 0-10 VDC control signal from the house control
Includes: sensor bracket

Spark Ignition Brooders

26487

Control: house control
Brooder Capacity: 24 (LP or NG)
Electrical Requirement: 24 VDC Power Supply and a 0-10 VDC control signal from the house control
Includes: sensor bracket

For information on the Smart Sense™ automatically managed Infraconic Radiant Brooder Heater, click here!

L.B. White Radiant Heat Brooders for Hog Buildings

Improve animal welfare, production, and profitability in pig complexes with the patented Infraconic. This radiant heat pig brooder leads the industry in heat efficiency, range of heat outputs, flexible installation and proven reliability.

L.B. White designed the Infraconic to save money on energy costs – up to 40% fuel cost savings depending on the facility condition and existing pig heating system.

The Infraconic provides a more consistent heat pattern than other brooders for pig production. As a result, pigs remain warm so they eat more and grow at a faster rate. Pork producers around the world rely on the L.B. White radiant heat brooder for farrowing, nursery and wean to finish phases of pig production.